Radiotherapy Application Spares Healthy Tissue, Improves Cancer Treatment

By HospiMedica International staff writers
Posted on 21 Feb 2011
Medical physicists have devised a new real-time tumor tracking technique that can help minimize the amount of radiation delivered to surrounding healthy tissue in a patient--up to 50% less in some cases--and maximize the dose the tumor receives. More...


Respiratory and cardiac motions have been shown to displace and deform tumors in the lung, pancreas, liver, breast, and other organs. Because of this, radiation oncologists must expand the margin during radiotherapy. Subsequently, a large volume of healthy tissue is irradiated, and critical organs adjacent to the tumor are sometimes difficult to spare. In an effort to reduce that margin, researchers from Thomas Jefferson University (Philadelphia, PA, USA) have developed a new four-dimensional (4D), robotic technique that better predicts and continuously tracks tumors during radiotherapy, preventing unnecessary amounts of radiation from being administered to unnecessary areas. Therefore, vital organs and tissues are spared; cancer treatment is potentially improved; and side effects are decreased.

Published in the online February 1, 2011, issue of Physics in Medicine and Biology journal, the study was coauthored by Ivan Buzurovic, PhD, a medical physics resident and researcher in the department of radiation oncology at Jefferson Medical College at Thomas Jefferson University, and Yan Yu, PhD, director of medical physics at Thomas Jefferson University.

In this technique, the robotic system--programmed with the proposed algorithms devised by Jefferson researchers--is automatically adjusted so that the position of the tumor remains stationary during treatment. "The advantage of this novel approach in radiation therapy is that the system is able to predict and track tumor motion in three-dimensional space,” said Dr. Buzurovic. The technique can compensate both tumor motion and residual errors during patient treatment, he added.

When active tracking was applied and tumor motion was up to 1.5 cm, irradiated planning target volume (PTV) was 20% - 30% less for medium size tumors and more than 50% for small size tumors. For tumor motion range up to 2.5 cm, irradiated PTV was two times smaller when tracking is applied. "The proposed robotic system needs 2 seconds to start tracking with the high precision level. The tracking error was less than 0.5 mm for regular breathing patterns and less than 1 mm for highly irregular respiration,” said Dr. Buzurovic. "Prediction algorithms were developed to predict tumor motion and to compensate errors due to delay in the system response.”

The study findings suggest that the use of tumor tracking technology during radiotherapy treatment for lung cancer would result in a considerable reduction in dose to the healthy tissue, potentially decreasing the probability or severity of side effects, coauthor Dr. Yu reported.

With this new technique, radiation oncologists would be able to administer more radiation and faster to the tumor than conventional methods, said Adam P. Dicker, M.D, PhD, professor and chairman of the department of radiation oncology at Thomas Jefferson University. "If we shrink our margin by this new robotic technique, then we can bring larger doses to tumors,” Dr. Dicker stated. "And a higher dose means a better cure in lung cancer, for instance.”

Researchers from the department of radiation oncology at the University of Michigan Hospital (Ann Arbor, MI, USA) and Brody School of Medicine at East Carolina University (Greenville, NC, USA) were also involved in the study. The researchers' method, demonstrated in extensive computer simulation, can be applied to two commercially available robotic treatment couches.

Related Links:

Thomas Jefferson University





Platinum Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Gold Member
12-Channel ECG
CM1200B
Premium Air-Mattress
MA-51
X-Ray Meter
Cobia SENSE
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image: Professor Bumsoo Han and postdoctoral researcher Sae Rome Choi of Illinois co-authored a study on using DNA origami to enhance imaging of dense pancreatic tissue (Photo courtesy of Fred Zwicky/University of Illinois Urbana-Champaign)

DNA Origami Improves Imaging of Dense Pancreatic Tissue for Cancer Detection and Treatment

One of the challenges of fighting pancreatic cancer is finding ways to penetrate the organ’s dense tissue to define the margins between malignant and normal tissue. Now, a new study uses DNA origami structures... Read more

Patient Care

view channel
Image: The portable biosensor platform uses printed electrochemical sensors for the rapid, selective detection of Staphylococcus aureus (Photo courtesy of AIMPLAS)

Portable Biosensor Platform to Reduce Hospital-Acquired Infections

Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.