Lower Ventilation Pressure Sufficient for Healthy Lungs

By HospiMedica International staff writers
Posted on 22 Dec 2020
Low positive end-expiratory pressure (PEEP) protocols for ICU patients without acute respiratory distress syndrome (ARDS) are no worse than higher levels, according to a new study. More...


Researchers at Amsterdam University Medical Centers (AMC; The Netherlands), Hospital Israelita Albert Einstein (São Paulo, Brazil), and other institutions conducted a study involving 980 patients (median age 66, 36% women) in eight ICUs in the Netherlands to determine if a lower PEEP strategy (0-5 cm H2O) was non-inferior to a higher PEEP strategy (8 cm H2O). All patients were without ARDS, and were not expected to be extubated within 24 hours of ventilation initiation. The primary outcome was the number of ventilator-free days at day 28.

The results showed that at day 28, patients in the lower PEEP group had a median of 18 ventilator-free days, while those in the higher PEEP group had a median of 17 ventilator-free days. Mortality was 38.4% versus 42%, occurrence of severe hypoxemia was 20.6% versus 17.6%, and need for rescue strategy was 19.7% versus 14.6%, respectively. In addition, there were no major differences in duration of ventilation, ICU, or hospital lengths of stay, pulmonary complications, and the other secondary endpoints. The study was published on December 9, 2020, in JAMA.

“There has been a gradual and noticeable increase in use of higher PEEP in patients without ARDS in ICUs worldwide,” concluded senior author Marcus Schultz, MD, PhD, of AMC, and colleagues. “It may not be better to use a lower PEEP strategy, but it could be as good as higher PEEP. These findings support the use of lower PEEP in patients without ARDS.”

Ventilation with higher PEEP may lead to a better distribution of lung aeration, improving oxygenation, and could even prevent ARDS. However, it could also worsen existing or cause new lung injuries, since ventilation with higher PEEP impairs blood hemodynamics and increases the need for additional fluid administration or vasopressors. And because it is common practice to extubate at lower PEEP, use of higher PEEP could also delay weaning in some settings. The study was concluded before the onset of the COVID-19 pandemic.

Related Links:
Amsterdam University Medical Centers
Hospital Israelita Albert Einstein



Platinum Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
Temperature Monitor
ThermoScan Temperature Monitoring Unit
Spirometry & Oximetry Software
MIR Spiro
Silver Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image: Professor Bumsoo Han and postdoctoral researcher Sae Rome Choi of Illinois co-authored a study on using DNA origami to enhance imaging of dense pancreatic tissue (Photo courtesy of Fred Zwicky/University of Illinois Urbana-Champaign)

DNA Origami Improves Imaging of Dense Pancreatic Tissue for Cancer Detection and Treatment

One of the challenges of fighting pancreatic cancer is finding ways to penetrate the organ’s dense tissue to define the margins between malignant and normal tissue. Now, a new study uses DNA origami structures... Read more

Patient Care

view channel
Image: The portable biosensor platform uses printed electrochemical sensors for the rapid, selective detection of Staphylococcus aureus (Photo courtesy of AIMPLAS)

Portable Biosensor Platform to Reduce Hospital-Acquired Infections

Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.