Stethoscopes Superior for Intrapartum Fetal Surveillance

By HospiMedica International staff writers
Posted on 21 Apr 2021
Stethoscope intermittent auscultation (IA) remains the best method for determining fetal distress during labor and delivery, according to a new study.

Researchers at the University of Warwick (Coventry, United Kingdom), the University of Birmingham (UB; United Kingdom), and other institutions undertook a systematic review and meta-analysis of published studies to evaluate the effectiveness of different types of intrapartum fetal surveillance. In all, 33 relevant studies were identified, involving 118,863 patients. The main focus of the review was on intrapartum emergency cesarean deliveries and other secondary maternal and neonatal outcomes.

The results showed that IA reduced the risk for emergency cesarean deliveries versus other types of surveillance, including cardiotocography (CTG), CTG with fetal scalp pH analysis (FBS), CTG with fetal scalp lactate, CTG with fetal pulse oximetry (FPO), and CTG with FBS and FPO. The results were similar for reduction in cesarean deliveries for fetal distress. However, there was no reduction in risk noted for neonatal acidemia, neonatal unit admissions, Apgar scores, or perinatal death for any of the evaluated methods. The study was published on April 6, 2021, in Journal of the Canadian Medical Association (CMAJ).

“Our analysis suggests that all additional methods introduced to improve the accuracy of electronic fetal heart monitoring have failed to reduce the risk of adverse neonatal or maternal outcomes beyond what IA achieved 50 years ago,” concluded lead author Bassel Al Wattar, PhD, of the University of Warwick, and colleagues. “Newer fetal surveillance methods did not improve neonatal outcomes or reduce unnecessary maternal interventions. Further evidence is needed to evaluate the effects of fetal pulse oximetry and fetal heart electrocardiography in labor.”

Monitoring the fetal heart rate to detect intrapartum hypoxia using simple surveillance techniques, such as the Pinard stethoscope, has been practiced for decades. CTG remains the most common surveillance method used in high-risk pregnancies; however, many researchers have evaluated its use in combination with other methods, such as fetal heart electrocardiogram, FBS, or fetal pulse oximetry (FPO) to improve its diagnostic value. However, the effectiveness of such methods in improving maternal and neonatal outcomes remains debatable, as stillbirth rates have plateaued worldwide, while cesarean delivery rates continue to rise.

Related Links:
University of Warwick
University of Birmingham



Platinum Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
Ultrasound System
FUTUS LE
Infant Resuscitator
Easypuff
Silver Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image: Miniaturized electric generators based on hydrogels for use in biomedical devices (Photo courtesy of HKU)

Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices

The development of engineered devices that can harvest and convert the mechanical motion of the human body into electricity is essential for powering bioelectronic devices. This mechanoelectrical energy... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.