Automated Venipuncture Device Facilitates Rapid Blood Draws

By HospiMedica International staff writers
Posted on 17 Feb 2020
A robotic venipuncture device can safely perform blood draws on peripheral forearm veins, according to a new study.

Developed at Rutgers University (Piscataway, NJ, USA) and Robert Wood Johnson University Hospital (New Brunswick, NJ, USA), the new device combines ultrasound imaging and near-infrared (NIR) light to locates the patient’s blood vessels and identify suitable vessels for cannulation. It then reconstructs the vessels in 3D using image analysis; finally, miniaturized robotics guide an attached needle toward the selected vein, inserting the needle right into the lumen center.

According to previous studies, venipuncture fail occurs in 27% of patients without visible veins, 40% of patients without palpable veins, and 60% of emaciated patients, even when done by professionals. But in recent clinical studies of the robotic device, it demonstrated results comparable to or exceeding that of clinical standards, with a success rate of 87% for all participants, a 97% success rate in non-difficult venous access cases, and with an average procedure time of just 93 seconds. The study was published on January 22, 2020, in Technology.

“A device like ours could help clinicians get blood samples quickly, safely and reliably, preventing unnecessary complications and pain in patients from multiple needle insertion attempts,” said lead author biomedical engineering doctoral student Josh Leipheimer, MSc. “In the future, the device could be used in such procedures as IV catheterization, central venous access, dialysis, and placing arterial lines. Next steps include refining the device to improve success rates in patients with difficult veins to access.”

Blood draw procedures occur 350 million times annually in the United States alone. Almost 28% of adult venipunctures and 44% of pediatric venipunctures draws require more than one stick to successfully draw blood, and around 10% of children 3-10 years old must be physically restrained for a needle-based blood draw. Repeated venipuncture failures also boost the likelihood of phlebitis, thrombosis, and infections, and may require targeting large veins in the body (or arteries) at much greater cost and risk.

Related Links:
Rutgers University
Robert Wood Johnson University Hospital



Platinum Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
Heavy-Duty Wheelchair Scale
6495 Stationary
Digital X-Ray Detector Panel
Acuity G4
External Defibrillator
HeartSave Y | YA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image: Miniaturized electric generators based on hydrogels for use in biomedical devices (Photo courtesy of HKU)

Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices

The development of engineered devices that can harvest and convert the mechanical motion of the human body into electricity is essential for powering bioelectronic devices. This mechanoelectrical energy... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.